Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Braz. j. oral sci ; 18: e191620, jan.-dez. 2019. ilus
Article in English | LILACS, BBO | ID: biblio-1095173

ABSTRACT

Aim: it was to use tridimensional finite element analysis (FEA) to analyze the effect of height and angulation of prosthetic preparations on the distribution of stresses for lithium disilicate prosthetic crowns, the underlying resin cement, and the prosthetic preparation of a superior central incisor. Methods: a CAD modeling software, SolidWorks 2013, was used to generate three-dimensional virtual models comprising the dimensions of the preparation parameters. Three angles (6, 12 and 16 degrees) were simulated on the prepared walls and two wall heights were utilized (4 and 5 mm), for a total of six model groups according to the height and angulation of the walls. A vertical line in the Y-axis was used as a reference for determining the degrees of convergence (inclination of the preparations). The chamfer finish and preparation width were standardized for all groups. Results: the 4 mm preparations behaved more appropriately when the axial wall convergence was approximately 6 degrees. The 5 mm preparations required 12 degrees of angulation. In relation to resin cement, there was better stress distribution when the angle of incisal convergence was between 6 and 12 degrees. An increase to 16 degrees led to a considerable increase in peak stress at the preparation margin. Conclusion: it was concluded that the convergence of the axial walls of coronal preparations with 4 and 5 mm heights should be 6 and 12 degrees, respectively, to avoid high tension spikes in the underlying resin cement


Subject(s)
Dental Prosthesis , Tooth Preparation , Finite Element Analysis , Incisor
2.
PróteseNews ; 2(4): 452-458, out.-dez. 2015. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-846764

ABSTRACT

Objetivo: este estudo avaliou a resistência à fratura de facetas confeccionadas sobre dois tipos de preparo. Métodos: utilizando-se dentes bovinos, dois grupos foram preparados: grupo I (redução incisal de 1 mm) e grupo II (redução incisal de 3 mm). Facetas laminadas foram enceradas sobre preparos dentais e confeccionadas em cerâmica IPS e.max (Ivoclar Vivadent). As superfícies internas das facetas foram tratadas com ácido fluorídrico a 10% durante 20 segundos e silanizadas. A superfície preparada do dente foi condicionada durante 15 segundos com ácido fosfórico a 37%, lavada abundantemente e secada levemente. O adesivo foi aplicado em duas camadas: dente e lado interno do laminado. A cimentação foi realizada com cimento resinoso fotopolimerizável sob pressão digital, e uma máquina de teste tipo pendular foi utilizada para simular o impacto no corpo-de-prova. Resultados: os dados de energia absorvida na fratura pelas facetas laminadas foram submetidos ao teste t de Student para amostras independentes (α = 5%), que demonstrou não haver diferença significativa entre os grupos com redução incisal de 1 mm e redução incisal de 3 mm (p=0,724). Observou-se, no grupo I, 10% das facetas laminadas com perda total, 30% extensa, mas parcial, e 60% parcial. Já no grupo II, 0% das facetas laminadas com perda total, 10% extensa, mas parcial, e 90% parcial. Conclusão: embora não tenha sido demonstradas diferenças na energia absorvida entre os dois tipos de preparo, o modo de fratura nos preparos com redução incisal de 3 mm foi mais favorável.


Objective: to evaluate the fracture resistance of laminate veneers on two preparation types. Methods: two groups were made based on bovine teeth: group I (1 mm incisal reduction) and group II (3 mm incisal reduction). All Laminate veneers were waxed over tooth preparations and fabricated with the IPS e.max ceramic (Ivoclar Vivadent). Their inner surfaces were treated with 10% hydrofluoric acid for 20 seconds and received a silane agent. The tooth surface was conditioned with 37% phosphoric acid, washed, and slightly dried. The adhesive was applied at the tooth and the laminate veneer. A photo-cured luting agent was used under fi nger pressure, and the samples were placed in an impact machine test. The fracture energy data was submitted to the Student´s t test for independent samples (5% significance level). Results: no statistical difference was observed (p = 0.724). At group I, 10% of the laminates demonstrated complete loss, 30% extensive but partial loss, and 60% partial loss. For group II, the figures were 0% for complete loss, 10% extensive but partial, and 90% partial. Conclusion: although no diff erences were seen for the absorbed energy, the 3 mm incisal reduction design was the most favorable.


Subject(s)
Cattle , Ceramics , Dental Cements , Dental Porcelain , Dental Veneers , Materials Science , Resin Cements
3.
RGO (Porto Alegre) ; 63(3): 257-262, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-765058

ABSTRACT

Objective: To investigate the biological effect of a new method to camouflage the cobalt-chromium (CoCr) metal structure of an RPD, onto which an electrostatic paint was applied.Methods: In vitro cytotoxicity of epoxy Politherm NOBAC30C (Weg Industries SA, Santa Catarina, Brazil) in combination with polished CoCr was tested by placing it in contact with cultured human fibroblasts and comparing it with polystyrene (control surface). The cells were cultured in the presence of the test surfaces for 24, 48, 72, 94 and 120 hours. The number of viable and non-viable cells was established by manual counting. The Tukey test was used to statistically analyze cell counts between the groups.Results: The results showed that cell proliferation was similar between the groups (p =0.2174). It was observed that at 24, 48 and 72 h, there was no significant increase in cell proliferation in all groups. From 96 to 120 h, an increase in cell proliferation was observed in all groups, with no significant difference between them (p>0.05).Conclusion: The epoxy paint studied showed no cytotoxicity in vitro.


Objetivos: Analisar, biologicamente, a possibilidade do uso de pintura por aplicação eletrostática.Métodos: Por meio de testes in vitro de citotoxicidade, comparando o comportamento da tinta epóxi Politherm 30 Nobac C (Weg Indústrias S.A, Santa Catarina, Brasil) com CoCr polido e poliestireno em contato com cultura de fibroblastos humanos. Esse teste foi realizado através de contagem de células viáveis e não viáveis em tempos de 24, 48, 72, 94 e 120 horas. Para a contagem de células viáveis foi aplicada a Análise Estatística de Tukey.Resultados: Os resultados obtidos na presente pesquisa mostraram que o comportamento de crescimento celular foi estatisticamente semelhante entre grupos (p=0,2174). Observou-se que nos tempos de 24, 48 e 72 horas, não houve aumento estatisticamente significante da proliferação celular, mantendo-se o padrão para todos os grupos estudados. A partir de 96 e 120 h observamos um aumento da proliferação celular para todos os grupos estudados, sem diferenças entre os mesmos também (p>0,05). Para os resultados de células inviáveis, aplicou-se a Análise não Paramétrica de Kruskal Wallis e o teste de Dunn, devido à baixa taxa de morte celular, sem diferença estatisticamente entre os grupos (p>0,05).Conclusão: Conclui-se, portanto, que a pintura Epóxi estudada não apresentou citotoxicidade para os testes realizados in vitro.

4.
ImplantNews ; 12(6): 813-820, nov.-dez. 2015. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-850955

ABSTRACT

Objetivo: avaliar in vitro a microinfiltração bacteriana na interface dos implantes entre os pilares tipo Ucla totalmente calcináveis e calcináveis com base pré-fabricada. Material e métodos: para este estudo, foram utilizados 20 implantes com conexão de hexágono externo, diâmetro 3,75 mm, comprimento de 11,0 mm e plataforma regular (4,1 mm): destes, em dez foram acoplados pilares protéticos fundidos a partir de peças calcináveis (nylon) por um laboratório comercial, em NiCr (grupo TC); nos demais implantes, adaptaram-se dez pilares fundidos sobre bases pré-fabricadas (cobalto-cromo), seguindo as recomendações do fabricante (grupo CM). Cada conjunto implante/pilar constituiu um corpo-de-prova. Os pilares calcináveis e os de bases pré-fabricadas foram incluídos em revestimento e, após o tempo de presa final, foram levados ao forno e fundidos em centrígufa manual com maçarico de gás e oxigênio. As peças foram desincluídas do revestimento, jateadas com óxido de alumínio 60 μm e usinadas com pedra de óxido de alumínio. Elas foram inoculadas com Escherichia coli e, em seguida, os pilares protéticos foram conectados imediatamente aos seus respectivos implantes e parafusados com torque de 32 Ncm, conforme recomendado pelo fabricante. Foram colocados em meio de cultura para observação da turvação nos períodos de um, dois, cinco, sete e 14 dias, para verificação da microinfiltração pela interface implante/pilar. Resultados: testes binominais revelaram que os pilares tipo Ucla com base pré-fabricada, em todos os tempos de análise, resultaram no turvamento de um menor número de meios de cultura. Conclusão: a microinfiltração bacteriana na interface do implante pode ser reduzida pela utilização de pilares tipo Ucla calcináveis com base pré-fabricada. Os pilares totalmente calcináveis mostraram infiltração logo nas 48 horas de teste. Uma falha na adaptação entre o implante e o pilar intermediário pode levar a falhas protéticas mecânicas e perda do tecido ósseo...


Objective: to assess the bacterial leakage at the implant-abutment interface using burnout and prefabricated UCLA abutment. Material and methods: twenty external hex implants (3.75 mm diameter, 11 mm length, regular platform 4.1 mm) were divided into two groups and received burnout abutments cast in a Ni-Cr alloy (TC = 10 samples) or Co-Cr prefabricated abutments (CM = 10 samples). An implant-abutment assembly constituted a sample. The burnout and prefabricated abutments were invested and further cast with a gas oxygen torch. After, samples were divested, sandblasted (60 μm aluminum oxide particles) and finished with appropriate aluminum oxide stones. Then, samples were inoculated with E. coli, and the prosthetic abutments fastened with a 32 Ncm torque as recommended by the manufacturer. After, the assemblies were immersed in a growth media to observe turbidity at 1, 2, 5, 7, and14 days later. Results: the binominal tests revealed lower turbidity numbers for Ucla prefabricated samples at all tested periods. Conclusion: the use of prefabricated UCLA abutments reduces the chance of leakage. In addition, burnout abutments demonstrated leakage in the first 48 hours. A lack of fit at the implant-abutment interface can lead to mechanical failures and peri-implant tissue loss due to bacterial contamination.


Subject(s)
Dental Implantation , Dental Leakage , Osseointegration , In Vitro Techniques
5.
RGO (Porto Alegre) ; 62(3): 229-234, Jul-Sep/2014. graf
Article in English | LILACS | ID: lil-732732

ABSTRACT

OBJECTIVE: Abrasion resistance of three commercial brands of acrylic resin for artificial teeth, available on the domestic market (Biotone(r), Plus(r) and Vipi Dent Artiplus(r)) was evaluated by a new methodology called "Pirassununga Method ". METHODS: The Manufacturers produced the maxillary central incisor-shaped incisal resin specimens (n=27). These were embedded in chemically activated acrylic resin in an insulated metal matrix to fabricate test specimens, which were flattened on a lathe and refined manually with sandpaper. Wear testing was conducted in an experimental machine at the Vipi dental products factory. In the "Pirassununga Method" a polished metal sphere 4.8 mm in diameter, attached to a rotary device passes over the fixed specimens in programmable cycles, under 5N pressure, using distilled water as lubricant. In each sample, the groove caused by abrasion, was analyzed in two ways: Readout under a microscope to determine the breadth and depth of the groove caused by the ball, and by laser roughness meter readout, which obtained a value Rt. RESULTS: The nonparametric Kruskal Wallis test showed no statistically significant difference between the medians of brands evaluated in the cycles performed (p = 0.936). CONCLUSION: Artiplus(r) Brand showed a lower tendency to wear than commercial brands Biotone(r) and Plus(r) Vipi Dent, with the best performance shown for the IPN polymer. .


OBJETIVO: Avaliar a resistência ao desgaste por abrasão de três marcas comerciais de dentes artificiais de resina acrílica disponíveis no mercado nacional (Biotone(r), Vipi Dent Plus(r) e Artiplus(r)) por meio de uma nova metodologia. MÉTODOS: Os corpos de prova foram produzidos pelos fabricantes, com resina incisal em forma de incisivos centrais superiores (n=27). Esses dentes foram incluídos em resina acrílica ativada quimicamente dentro de uma matriz de metal isolada para confecção dos corpos de prova, e depois aplainados em torno mecânico e refinados com lixa d'agua manualmente. O ensaio do desgaste foi realizado em uma máquina experimental presente na fábrica de produtos odontológicos Vipi. No "Método Pirassununga" uma esfera metálica polida de 4,8 mm de diâmetro presa em um dispositivo que rotaciona, passa sobre os corpos de prova que estão fixos, em ciclos que podem ser programados, e tendo água destilada como lubrificante e pressão de 5N. O sulco provocado pela abrasão em cada corpo de prova foi analisado de duas maneiras: Leitura em microscópio para determinar a largura e a profundidade do sulco provocado pela esfera e rugosímetro de leitura a laser, do qual foi obtido o valor Rt. RESULTADOS: Por meio do teste não paramétrico de Kruskal Wallis observou-se que não houve diferença estatisticamente significante entre as medianas das marcas avaliadas nos ...

6.
RGO (Porto Alegre) ; 61(3): 369-374, jul.-set. 2013. ilus, tab
Article in English | LILACS | ID: lil-691753

ABSTRACT

Objective: To evaluate the shear bond strength of a feldspathic ceramic cemented to a composite resin using a resin-based cement, following different treatments to the ceramic surface. Methods: 30 ceramic samples were prepared and divided into 3 groups according to surface treatment: group 1 - control, group 2 - 10% hydrofluoric acid etching for 2 minutes, rinsing under running water and air-drying, group 3 - 10% hydrofluoric acid for 2 minutes, rinsing under running water, air-drying followed by silane. Subsequently, composite resin discs were cemented onto the ceramic specimens using a resin cement and light-curing for 40 seconds. Shear bond strength test was performed on an Emic DL2000 testing machine. Results: Statistical analysis revealed the following results: there was a significant increase in bond strength in the group etched with hydrofluoric acid when compared with the control, whilst no significance was found in the group treated with silane after etching. Conclusion: The assessment of failure types under light microscopy revealed a predominance of adhesive failures in the control group and cohesive failures in the remaining groups.


Objetivo: Avaliar a resistência ao cisalhamento de uma porcelana feldspática, submetida à diferentes tratamentos superficiais, cimentada a uma resina composta, utilizando-se um cimento resinoso. Métodos: Foram confeccionadas 30 amostras de porcelana, divididas em 3 grupos e receberam os seguintes tratamentos de superfície: Grupo1 - grupo controle; Grupo2 - tratada com ácido fluorídrico 10% por 2 minutos, lavada em água corrente e secada com jatos de ar; Grupo3 - tratada com ácido fluorídrico a 10% por 2 minutos, lavada em água corrente, secada com jatos de ar e silanizada. Na seqüência foi realizada a cimentação dos discos de resina composta na porcelana, com cimento resinoso e fotopolimerizado por 40 segundos. O teste de cisalhamento foi realizado numa máquina Emic DL2000. Resultados: Após análise estatística chegou-se aos seguintes resultados: houve um aumento significativo na resistência adesiva nos grupos que sofreram condicionamento da superfície da porcelana, em relação ao grupo controle. A aplicação do silano nas porcelanas condicionadas pelo ácido fluorídrico, não foi significante. Conclusão: Na análise das falhas em microscópio ótico, predominaram as adesivas no grupo controle, e as coesivas nos demais grupos.


Subject(s)
Resin Cements , Dental Porcelain , Composite Resins , Shear Strength
7.
Rev. odontol. UNESP (Online) ; 42(5): 384-388, set.-out. 2013. ilus
Article in English | LILACS, BBO | ID: lil-690731

ABSTRACT

Introdução: Em pacientes com bruxismo, a atrição pode resultar em desgaste oclusal excessivo que excederá o mecanismo compensatório e ocorrerá uma perda de dimensão vertical de oclusão. Objetivo: O propósito deste artigo é mostrar a importância do restabelecimento de um adequado plano oclusal no arco não restaurado por meio de uma overlay fixa de acrílico, compatível com o tratamento protético do arco a ser reabilitado. A recuperação do plano oclusal do paciente na maxila com uma overlay de resina acrílica numa apropriada dimensão vertical de oclusão simultaneamente com uma prótese fixa na mandíbula, suportada por 5 implantes dentais é detalhada. Conclusão: Quando há um severo desgaste devido ao atrito dental em um dos arcos, é importante restabelecer o plano oclusal e as curvas de compensação simultaneamente com a restauração protética do arco a ser reabilitado.


Introduction: In patients with Bruxism, the attrition can result in excessive occlusal wear that exceeds the compensatory mechanism and loss of occlusion vertical dimension occurs. Objective: The purpose of this article is to show the importance of re-establishing an adequate occlusal plane for the non treated arch by means of a fixed acrylic overlay, compatible with the prosthetic treatment of the arch to be rehabilitated. An upper maxillary fixed acrylic overlay restored the patient’s occlusal plane in an appropriate vertical dimension of occlusion together with a fixed prosthesis in the mandible, supported by five dental implants. Conclusion: When there is severe wear due to dental attrition in one of the arches, it is important to re-establish the occlusal plane and compensation curves in conjunction with the prosthetic treatment of the arch to be rehabilitated.


Subject(s)
Vertical Dimension , Acrylic Resins , Bruxism , Dental Implants , Centric Relation , Dental Prosthesis, Implant-Supported , Dental Occlusion
8.
Rev. dental press estét ; 10(1): 97-107, jan.-mar .2013. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-681623

ABSTRACT

Avaliar por meio de análise rugosimétrica e imagens de microscopia eletrõnica de varredura, a rugosidade superficial (Ra) de duas cerâmicas odontológicas, após simulação de ajuste com brocas diamantadas e diferentes tratamentos de polimento. Foram confeccionados dois grupos de corpos de prova, sendo (G1) a cerâmica CCS de alta fusão e, o segundo grupo (G2), a cerâmica Duceram LFC de baixa fusão. Para cada cerâmica foram confeccionados 20 corpos de prova, separados em quatro subgrupos. Na primeira etapa desse trabalho, tanto em G1 quanto em G2, os maiores valores de Ra foram encontrados no tratamento T3. Na segunda etapa, os corpos de prova foram analisados por MEV e notou-se que as fotografias de T3 aparecem em ambos os grupos com aumento de poros e riscos na superfície. Foi encontrada correlação entre os dados do rugosímetro e das fotomicrografias de MEV; e alguns processos de polimento, como T2, produzem superfície semelhantes à glazeada quando analisada quantitativamente, no entanto, com maior quantidade de riscos e poros quando analisadas qualitativamente e comparadas à superfície glazeada (T1) e reglazeada (T4)


Objectives: To analyze using a perflometer, with Ra parameter and scanning electron microscopy images of the surface of two dental ceramics after simulation of adjustment with diamonds drills and different treatments of polishing. Methods: Two groups with 20 samples each have been used: Group G1 ­ Carmen CCS ceramics, and the group G2 ­ Duceram LFC ceramic. Each group were divided in four sub-groups.Results: The results showed that in G1 and G2 groups the higher values of Ra was found in treatment T3. The samples have been analyzed in SEM and it was found a connection between the perflometer data and SEM micrographs. The micrographs of T3 showed in the G1 and G2 groups an increase of porosities and risks on the surface. Conclusion: Then, it can be concluded that some processes of polishing, like T2 treatment, can produce a surface similar the control group (T1), when analyzed quantitatively, however, with a higher amount of risks and porosities when analyzed qualitatively and compared to T1 and T4 surface treatments.


Subject(s)
Esthetics, Dental , Microscopy, Electron, Scanning , Dental Polishing/methods , Surface Properties
9.
ImplantNews ; 10(6a): 69-72, 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-761259

ABSTRACT

Com a consolidação e a popularização do uso de implantes osseointegrados na reabilitação de pacientes edêntulos, um dos aspectos que merece a atenção dos profissionais na Odontologia é o desenvolvimento de novos materiais para a confecção de infraestruturas para restaurações implantossuportadas. Este trabalho in vitro verificou a resistência à fratura de infraestruturas de zircônia com cantiléver a 9 mm e 18 mm do centro do último implante. Por meio de um gabarito em cobalto-cromo, simulando uma infraestrutura de prótese com cantiléver distal, foram confeccionados 20 corpos-de-prova, que foram divididos em dois grupos (n=10), de acordo com a localização da carga aplicada durante o teste de fratura. Em uma máquina de ensaio universal, aplicou-se uma força compressiva perpendicular à infraestrutura sobre o cantiléver a 9 mm e 18 mm do centro do último implante mais distal, até ocorrer fratura da mesma, quando se verificou a carga máxima. Os resultados foram submetidos ao teste t Student, que apontou que a resistência à fratura nas infraestruturas foi significativamente superior (p < 0,0001) no grupo em que a carga foi aplicada a 9 mm, que apresentou resistência média de 590,3 N (dp=99,1 N), enquanto o grupo onde a carga foi aplicada a 18 mm apresentou o valor médio de resistência à fratura de 181,2 N (dp=32,5 N). Concluiu-se que quanto maior a extensão do cantiléver menor é a força necessária para induzir uma fratura neste tipo de infraestrutura...


Due to consolidation and popularization of dental implants in the rehabilitation of edentulous patients, the development of new materials for framework fabrication on implant-supported restorations is one aspect that deserves professional attention in Dentistry. This in vitro study examined the fracture strength of yttria-stabilized zirconia infrastructures being the load applied at two different cantilever lengths. Twenty samples were made based on a Cobalt- Chrome pattern with a distal cantilever and divided into two groups (n=10). A compressive force was applied perpendicular to the infrastructure on the cantilever at 9 mm (G9) and 18 mm (G18) from the center of the last distal implant. The maximum load to failure was registered Mean fracture strength of the yttria-stabilized zirconia infrastructures was significantly higher (Student’s t test, p < 0.0001) for G9 (590.3 ± 99.1 N) than in the G18 (181.2 ± 32.5 N). It was concluded that the greater the length of the cantilever, the lower the force needed to induce fracture on yttria-stabilized zirconia frameworks...


Subject(s)
Humans , Dental Implants , Osseointegration
10.
RGO (Porto Alegre) ; 60(1): 55-59, jan.-mar. 2012. ilus, tab
Article in English | LILACS, BBO | ID: biblio-874562

ABSTRACT

Objective: The aim of this research was to compare the degree of dimensional stability and accuracy of Sapphire (Bosworth, Skokle, Illinois, EUA), which is an ethyl methacrylate acrylic resin, with polyvinyl siloxane (ADSIL-Vigodent, Rio de Janeiro, Brazil), a very accurate material of worldwide use. Methods: The materials were tested by two techniques, the one-step putty and two-step putty-wash impression techniques. Stone casts were produced from impressions of an aluminum master cast of an edentulous maxilla. The samples were divided into four groups of 15 impressions each: Group 1 - putty-wash impression with Sapphire (putty) and Adsil Fluido (wash); Group 2 - putty impression with Sapphire; Group 3 - putty impression with Adsil Regular (putty); Group 4 - putty-wash impression with Adsil Regular (putty) and Adsil Fluido (wash). Measurements were done by the B251 Mitutoyo Coordinate Measuring Machine (Mitutoyo Co., Suzano, Brazil). The statistical treatment included calculating the mean, variance and standard deviation of the samples. The significance level was set at 5% (p<0.05). The distances found for each group were compared with those of the master cast by the t-test. Results: Sapphire putty impressions presented the best dimensional stability. On the other hand, polyvinyl siloxane putty (Adsil) presented significantdimensional variations in samples produced from putty and putty-wash impressions. When Sapphire (Bosworth, Skokie, Illinois, EUA) and Adsilwere used together (putty-wash), Sapphire (Bosworth, Skokie, Illinois, EUA) improved the results of the putty-wash impressions. Conclusion: In conclusion, Sapphire (Bosworth, Skokie, Illinois, EUA) is a reliable and stable material that can be used for complete denture impressions.


Objetivo: Comparar o nível de fidelidade e precisão do Sapphire (Bosworth, Skokle, Illinois, EUA), uma resina acrílica modificada, com um polivinilsiloxano (Adsil - Vigodent, Rio de Janeiro, Brasil), um material considerado de alta fidelidade e amplo uso. Métodos: Os materiais foram empregados em duas técnicas: moldagem simples e moldagem dupla. Os modelos em gesso foram construídos a partir de moldes obtidos do modelo padrão metálico de alumínio que reproduz uma maxila edêntula. Foram estabelecidos 4 grupos de 15 moldagens assim divididos: Grupo 1 - Sapphire reembasado com Adsil Fluido; Grupo 2 - Sapphire com camada única; Grupo 3 - Adsil Regular com camada única e Grupo 4 - Adsil Regular mais Adsil Fluido com camada dupla. As medidas foram realizadas por um aparelho de medição por coordenadas B251(Mitutoyo Co., Suzano, Brasil). Na análise estatística foram calculados a média, variância e o desvio padrão das amostras (nível de significância<0,05). Em seguida foi feita uma comparação da distancia encontrada em cada grupo com o valor padrão através do teste t para uma amostra.Resultados: O Sapphire (Bosworth, Skokie, Illinois, EUA), em moldagem simples, apresentou melhores resultados em relação à estabilidade dimensional. Ao contrário do silicone de adição (Adsil, Rio de Janeiro, Brasil) que apresentou variações dimensionais significativas nos modelos obtidos por moldagem simples e também em moldagem dupla. O Sapphire (Bosworth, Skokie, Illinois, EUA) melhorou os resultados do silicone de adição ao ser misturado com este em moldagem dupla. Conclusão: Pode-se concluir que o Sapphire (Bosworth, Skokie, Illinois, EUA) é um material de moldagem fiel e de uso viável para moldagens em PróteseTotal.


Subject(s)
Denture, Complete , Acrylic Resins , Dental Impression Technique , Dental Prosthesis
11.
ImplantNews ; 6(3): 291-297, maio-jun. 2009.
Article in Portuguese | LILACS, BBO | ID: lil-523923

ABSTRACT

O objetivo deste trabalho é demonstrar a viabilidade clínica da carga imediata em mandíbula pela elucidação de um caso clínico no qual se conseguiu estética e função satisfatórias. A explanação do caso é precedida por uma breve revista literária onde a maioria dos autores é concorde com a execução da carga imediata, tipo protocolo mandibular, em casos onde não haja contraindicações sistêmicas e que a estabilidade primária e a qualidade óssea estejam asseguradas. Os autores concluem que este procedimento clínico é um recurso viável no campo da reabilitação oral e, dentro das indicações de utilização, devolve estética e função com maior comodidade ao paciente.


The aim of this paper is to present the clinical viability of the immediate loading in jaw through the briefing of a clinical case report in which the aesthetic and function were satisfactorily obtained. The explanation of the case is preceded by a brief literature review, where most of the authors agree with the execution of immediate loading on the lower jaw, in cases where it does not have systemic contraindications, and that the primary stability and the quality of the bone are assured. The authors conclude that this clinical procedure is a viable resource for oral rehabilitation procedures and, within its indications, regains aesthetic and function to achieve patient´s comfort.


Subject(s)
Humans , Male , Aged , Dental Prosthesis Retention , Dental Prosthesis, Implant-Supported , Mouth Rehabilitation
12.
ImplantNews ; 6(4): 405-410, 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-544180

ABSTRACT

A osseointegração, histologicamente, é definida por Brånemark como "uma conexão entre a loja óssea e um implante endósseo microscópico". O conceito da carga imediata tem se tornado popular devido a redução do trauma e tempo de tratamento, diminuição da ansiedade e desconforto do paciente, aceitação melhor do tratamento e melhores função e estética. O presente artigo mostra o sucesso de um caso clinico de prótese unitária sobreimplante com carga imediata.


Osseointegration is defined by Brånemark as "a connection between living bone and an endosseous implant at the light microscope and histological level". The concept of immediate implant loading has become popular due to less trauma, reduced overall treatment time, decreased patient's anxiety and discomfort, high patient acceptance and better function and esthetics. The present article shows the success of a clinical case of an immediate loaded, single-tooth, implant-supported prosthesis.


Subject(s)
Humans , Female , Adult , Dental Implants, Single-Tooth , Dental Implants , Osseointegration , Prostheses and Implants
13.
Rev. dental press estét ; 5(3): 107-112, jul.-set. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-543699

ABSTRACT

Atualmente, em muitos dos procedimentos odontológicos, são aplicadas técnicas restauradoras adesivas. O objetivo deste trabalho foi demonstrar, através de um caso clínico, a possibilidade de se realizar a manutenção de espaço interdentário, devido à perda precoce do primeiro molar permanente, a fim de se buscar uma reabilitação dentária futura. Para isto, utilizaram-se procedimentos adesivos e minimamente invasivos. Sugeriu-se a realização de um "mantenedor de espaço" fixo com auxílio das fibras de vidro para reforço (Interlig - Angelus), associadas aos cerômeros (solidex - Shofu). Concluiu-se que a alternativa clínica descrita atendeu às necessidades funcionais e estéticas da paciente.


Subject(s)
Humans , Female , Adolescent , Space Maintenance, Orthodontic , Occlusal Adjustment , Resin Cements , Dentin-Bonding Agents , Denture, Partial, Fixed , Mouth Rehabilitation
14.
Ciênc. odontol. bras ; 10(1): 6-11, jan.-mar. 2007.
Article in English | LILACS, BBO | ID: lil-518096

ABSTRACT

The metal restorations are used in Dentistry a long time ago. Nowadays we have resources that can get casting moreaccurate, with new material and equipments and techniques more precise. The purpose of this study was to evaluate themetallurgical and mechanical aspects of the AgPd dental alloy when it was submitted to different casting temperatures. Itwas used 30 specimens, divided in three groups (n=10): a) control group (no cast); b) casting temperature in accordancewith the manufacturesÆ instructions (T1); b) casting temperature above manufacturesï instructions (like a torch) (T2). Itwas evaluated chemical and metallographic aspects, mechanical properties and Vickers hardness. The results showed amicrostructure similar to T1 and T2 conditions, but with greater amount of light phase and particles in this last one. It wasobserved that the rupture tensile strength for the T1 condition was greater than the T2. The alloy in the no cast conditionpresented greater hardness but there was no statistically significant difference between T1 and T2. Supporting by themetallographic and mechanical results, it may predict that when elevated temperatures was used, above manufactureïsrecommendations, it can occur failures in the prosthesis, like porosities, fissures or cracks.


Subject(s)
Dental Alloys , Dental Casting Technique , Materials Testing
15.
RGO (Porto Alegre) ; 54(1): 62-66, jan.-mar. 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-445007

ABSTRACT

As Próteses Parciais Removíveis (PPR) do tipo dentomucosossuportadas são consideradas as mais complexas devido aos diferentes tipos de suporte encontrado, com as quais se busca minimizar os efeitos da diferença de compressibilidade do ligamento periodontal e da mucosa do rebordo residual durante a função mastigatória. A utilização de barras bi-partidas constitui uma das alternativas para diminuir essa discrepância. Essas estruturas têm a capacidade de transmitir aos segmentos mucosossuportados esforços contrabalançados e intermitentes, reduzindo a reabsorção do osso alveolar. Assim, os objetivos deste trabalho foram analisar, por meio da fotoelasticidade, um sistema de barra bi-partida para PPR a grampo e observar a distribuição interna das tensões geradas quando este dispositivo era empregado sobre o rebordo residual e o periodonto dos dentes pilares em um arco Classe I de Kennedy inferior. Os resultados mostraram que duas regiões chamam a atenção no rebordo residual: uma localizada no terço médio e outra na região distal da mesma estrutura. Não foram observadas alterações na região do rebordo sob o 1º pôntico da sela bi-partida. Observou-se nos dentes pilares um aumento de tensão nos ápices. Pela análise dos resultados obtidos foi possível concluir que a estrutura metálica bi-partida avaliada produziu tensões no rebordo residual e promoveram um alívio nos dentes pilares, sendo então indicada para os casos onde os dentes encontram-se com suporte periodontal reduzido e o rebordo apresente condições favoráveis.


Subject(s)
Humans , Dental Clasps , Denture, Partial, Removable , Dental Prosthesis Retention/methods
16.
Braz. j. oral sci ; 4(15): 923-928, Oct.-Dec. 2005. ilus, tab
Article in English | LILACS, BBO | ID: lil-472547

ABSTRACT

Metalloceramic restorations combine the aesthetic properties of ceramic materials with the high strength of metals. The titanium has excellent biocompatibility, good mechanical properties and low density, and has been recently used for metalloceramic prosthesis. The purpose of this study was to evaluate the shear bond strength of these two materials, and also analyze their bonding interface using Scanning Electron Microscopy (SEM). Thirty-six specimens were prepared and divided in three groups: Group 1- gold alloy (Degudent U-Degussa) + Vita Omega 900 ceramic(Vita) (control group); Group 2 – milled commercially pure titanium (cpTi- Dentaurum) + Titankeramik ceramic (Vita); Group 3 – cast and milled commercially pure titanium (cpTi-Dentaurum) + Titankeramik ceramic(Vita). The shear bond strength mechanical assay was performed in an Instron 4301 machine with capacity for 500Kg. After the test completion, surfaces were evaluated using SEM. The numerical results, put in tables, were: G1= 40,55MPa (+/- 4,8), G2= 63,54 MPA (+/- 1,73) and G3= 68,17 MPA (+/- 1,19). The statistical analysis (ANOVA) showed no significant statistically differences between groups G2 and G3 and the values were larger (significant statiscally) than G1. It is concluded that the titanium alloys is a good alternative to gold alloys to metalloceramic restorations emphasizing that it is cheaper, biocompatible and is has a low density.


Subject(s)
Gold Alloys , Metal Ceramic Alloys , Microscopy, Electron, Scanning , Titanium , Dental Alloys , Dental Materials , Shear Strength
17.
São José dos Campos; s.n; 2003. 99 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-494855

ABSTRACT

As restaurações metalocerâmicas combinam a resistência das ligas metálicas com a qualidade estética dos materiais cerâmicos. O titânio apresenta biocompatibilidade, boas propriedades mecânicas e baixa densidade, tendo sido recentemente utilizado em restaurações, metalocerâmicas. O objetivo desse trabalho foi quantificar a resistência ao cisalhamento entre titânio comercialmente puro (Ticp - Tritan - Dentaurum), em duas condições diferentes, e duas cerâmicas (Triceram - Dentaurum e Titankeramik - Vita) e comparar com um grupo controle com liga à base de ouro (Degudent U - Degussa - Hülls) e cerâmica dedicada (Omega 900 - Vita). Foram confeccionados 60 corpos-de-prova divididos em cinco grupos de doze: G 1 (grupo controle) - liga à base de ouro + cerâmica; Grupo G2 - titânio comercialmente puro usinado + cerâmica (Triceram), Grupo G3 - titânio comercialmente puro usinado + cerâmica (Titankeramik), Grupo G4- titânio comercialmente puro fundido e usinado + cerâmica (Triceram) e Grupo GS- titânio comercialmente puro fundido e usinado + cerâmica (Titankeramik). O ensaio mecânico foi realizado em máquina de ensaio universal (Instron 4301) com célula de carga de 500kg e a uma velocidade de 0,5mm/min utilizando um dispositivo específico. Os resultados numéricos lançados em tabela foram: G 1 = 40,55MPa (+/- 4,8), G2= 62,71MPa (+/- 2,12), G3= 63,56MPa (+/- 1,73), G4= 65,67MPa (+/- 6,7) e G5= 68,16MPa (+/- 1,19). O tratamento estatístico (ANOVA e Kruskal-Wallis) demonstrou que não houve diferenças estatísticas significantes entre os grupos G2, G3 e G4 e os todos os grupos obtiveram superiores aos do G 1. A microscopia eletrônica de varredura mostrou que as falhas foram principalmente coesivas da porcelana. Considerando o ensaio mecânico aplicado e os resultados obtidos, parece-nos lícito concluir que, tanto o titânio (cp) usinado quanto o fundido e usinado são alternativas viáveis na confecção de restaurações metalocerâmicas.


Subject(s)
Ceramics , Gold Alloys , Shear Strength , Titanium , Microscopy, Electron, Scanning
SELECTION OF CITATIONS
SEARCH DETAIL